  Datasheet File OCR Text:
  general purpose relays industrial relays prd series power relay 08-2011, rev. 0811 www.te.com ? 2011 tyco electronics corporation, a te connectivity ltd. company datasheets and product specifcation according to iec 61810-1 and to be used only together with the defnitions section. datasheets and product data is subject to the terms of the disclaimer and all chapters of the defnitions section, available at http://relays.te.com/definitions datasheets, product data, defnitions sec - tion, application notes and all specifcations are subject to change. 1 potter & brumfeld contact ratings (continued) type load cycles ul 508 1) models with screws or quick connects for main terminals code f, agcdo, 1 pole 50a, 240vac, general purpose 2) 20x10 3 30a, 277vac, resistive 100x10 3 1.5hp, 120vac 100x10 3 2hp, 250vac 100x10 3 10a, 600vac 100x10 3 code f, agcdo, 2 pole 50a, 240vac, general purpose 2) 20x10 3 30a, 240vac 100x10 3 20a, 277vac 100x10 3 1.5hp, 120vac 100x10 3 2hp, 250vac 100x10 3 10a, 600vac 100x10 3 2) in order to achieve 50a rating with contact code f, termination code 0 or a is required. code h, ag with magnetic blowout, 1 or 2 pole 20a, 125vdc 100x10 3 1/3hp, 125vdc 100x10 3 code j, agcdo with magnetic blowout, 1 or 2 pole 20a, 125vdc 100x10 3 1/3hp, 125vdc 100x10 3 code n, w stationary with agcdo movable, 1 or 2 pole 25a, 250vac 100x10 3 1hp, 125vac 100x10 3 2hp, 250vac 100x10 3 ul 508 1) models with box lugs for main terminals code p, ag, 1 form x 50a, 277vac, general purpose 100x10 3 30a, 277vac, ballast 6x10 3 15a, 277vac, tungsten 6x10 3 102lra, 17fla, 240vac 30x10 3 120lra, 20fla, 120vac 30x10 3 1.5hp, 120vac 30x10 3 3hp, 240vac 30x10 3 factory ratings models with box lugs for main terminals code r, ag with magnetic blowout, 1 form x 60a, 28vdc, resistive 100x10 3 30a, 125vdc 100x10 3 mechanical endurance dc coil, 1x10 6 ops.; ac coil 5x10 5 ops. auxiliary snap-action switch contact data contact arrangement 1 form c (co) rating 5a, 120vac, 60 hz., 25c contact material ag n contact ratings to 50 amps n magnetic blowouts available for switching dc loads n contact arrangement up to 2 form c (2co) n 1 form c auxiliary switch available n ul class b insulation typical applications industrial controls, lighting approvals ul e22575; csa lr15734; vde reg.nr.c144 models with all screw terminals are ul listed. others are ul recognized. technical data of approved types on request contact data contact arrangement 1 and 2 form a (no); 1 and 2 form c (co); 1 form x (no-dm) rated voltage 600vac,125vdc rated current 50a contact material ag, agcdo, w min. recommended contact load 1a, 12vdc or 12vac initial contact resistance 75m? max initial voltage drop 75mv frequency of operation 7200 ops/hr operate/releases time max. 40/20ms bounce time max. 10ms contact ratings type load cycles ul 508 1) models with screws or quick connects for main terminals code y, ag, 1 pole 25a, 277vac 100x10 3 1hp, 120vac 100x10 3 2hp, 250vac 100x10 3 10a, 600vac 100x10 3 7a, 50vdc, resistive 100x10 3 code y, ag, 2 pole 25a, 240vac 100x10 3 20a, 277vac 100x10 3 1hp, 120vac 100x10 3 2hp, 250vac 100x10 3 7a, 50vdc, resistive 100x10 3 10a, 600vac 100x10 3 code g, agcdo, 1 pole 30a, 277vac, resistive 100x10 3 1.5hp, 120vac 100x10 3 2hp, 250vac 100x10 3 10a, 600vac 100x10 3 code g, agcdo, 2 pole 30a, 240vac 100x10 3 20a, 277vac 100x10 3 1.5hp, 120vac 100x10 3 2hp, 250vac 100x10 3 10a, 600vac 100x10 3 1) any prd relay deviating electrically or physically from the standard models in the table is not ul or csa listed. all horsepower ratings are for single phase motors..
general purpose relays industrial relays prd series power relay (continued) 08-2011, rev. 0811 www.te.com ? 2011 tyco electronics corporation, a te connectivity ltd. company datasheets and product specifcation according to iec 61810-1 and to be used only together with the defnitions section. datasheets and product data is subject to the terms of the disclaimer and all chapters of the defnitions section, available at http://relays.te.com/definitions datasheets, product data, defnitions sec - tion, application notes and all specifcations are subject to change. 2 potter & brumfeld insulation data initial dielectric strength between open contacts 2000v rms between contact and coil 2000v rms between adjacent contacts 2000v rms initial insulation resistance between insulated elements 100m? other data material compliance: eu rohs/elv, china rohs, reach, halogen content refer to the product compliance support center at www.te.com/customersupport/rohssupportcenter ambient temperature ac coil: -55oc to 45oc dc coil: -55c to 80c category of environmental protection iec 61810 rt0 - open relay terminal type screw, quick connects, box lugs weight 284g packaging/unit tray/20 pcs., box/40pcs. accessories product code description 35d013 metal dust cover coil data coil voltage range 6 to 110vdc 6 to 480vac coil insulation system according ul class b coil versions, dc coil coil rated operate release coil rated coil code voltage voltage voltage resistance power vdc vdc vdc ?10% w 6 6 4.5 0.6 18 2 12 12 9 1.2 71 2 24 24 18 2.4 288 2 48 48 36 4.8 1150 2 110 110 82.5 11 6050 2 all fgures are given for coil without preenergization, at ambient temperature +23c. other coil voltages on request. coil versions, ac coil coil rated operate release coil rated coil code voltage voltage voltage resistance power vac vac vac ?15% va 6 6 5.1 0.6 0.86 9.8 12 12 10.2 1.2 3.2 9.8 24 24 20.4 2.4 12 9.8 120 120 102 12 290 9.8 240 240 204 24 1200 9.8 480 480 408 48 4500 9.8 all fgures are given for coil without preenergization, at ambient temperature +23c. other coil voltages on request. dimensions prd/prda 1, 3, 5 and 7 prd/prda 11 prd-3_p and r 2.28 max. (57.9) .375 (9.53) .31 (7.9) 1.875 (47.63) 2.50 (63.5) 2.5 max. (64) .81 (20.6) .59 max. (15.0) box lug connector .875 max. (22.23) 1.687 (42.85) 3.375 max. (85.73) .31 (7.9) 1.875 (47.63) 2.51 max. (63.8) 1 2 3 4 5 6 7 8 4.250 max. (107.95) 3.00 (76.2) .375 (9.53) 2.50 max. (63.5) 3.375 max. (85.73) w/o aux switch .375 (9.53) 2.23 (56.6) 3.375 (85.73) 2.28 max. (57.9) 2.50 max. (63.5) on prd7 2 4 6 3 1 5 .187 + .005 ? .003 4.75 + .13 ? .08 1.875 (47.63) 2.51 max. (63.75) .31 (7.9) 2.5 max. (63.3) .81 (20.6) .875 max. (22.23) 2.5 max. (63.5) w/o aux switch coil coil coil 5 6 2 1 ( ) 2 mtg. holes dia. .187 + .005 ? .003 4.75 + .13 ? .08 ( ) 2 mtg. holes dia. .187 + .005 ? .003 4.75 + .13 ? .08 ( ) 2 mtg. holes dia.
general purpose relays industrial relays prd series power relay (continued) 08-2011, rev. 0811 www.te.com ? 2011 tyco electronics corporation, a te connectivity ltd. company datasheets and product specifcation according to iec 61810-1 and to be used only together with the defnitions section. datasheets and product data is subject to the terms of the disclaimer and all chapters of the defnitions section, available at http://relays.te.com/definitions datasheets, product data, defnitions sec - tion, application notes and all specifcations are subject to change. 3 potter & brumfeld product code structure typical product code prd -7 a y 0 -120 type prd open relay prda open relay with aux. 1 form c (co) snap-action switch main contact arrangement 1 1 form a (1 no) 3 1 form x (1 no-dm) 5 1 form c (1 co) 7 2 form a (2 no) 7v 2 form a (2 no) with 3mm contact gap 1) 11 2 form c (2 co) 1) code 7v is only available as a ul recognized model, not ul listed coil input a ac, 50/60hz d dc main contact material and type y .312 (7.92mm) dia. ag [25a max. rating] g .312 (7.92mm) dia. agcdo [30a max. rating] f .312 (7.92mm) dia. agcdo [50a max. rating] 2) h ag with magnetic blowout [20a dc max. rating] 3) j agcdo with magnetic blowout [20a dc max. rating] n w stationary & agcdo movable [25a max. rating] 4) p ag [50a max. rating] 5) r ag with magnetic blow out [50a max. rating] 5) 2) available with main contact arrangement code (step 2 above) 1, 5, 7 or 11 only, and termination code (step 5 below) 0 or a only. 3) available with main contact arrangement code (step 2 above) 3, 7 or 11 only 4) available with main contact arrangement code (step 2 above) 1, 5, 7 or 11 only. 5) available with main contact arrangement code (step 2 above) 3 only, and termination code (step 5 below) 4 only. termination prd types only 0 #8-32 screw term. for main contacts, #6-32 screw term. for coil. 1 .250 (6.35mm) qc for main contacts and coil 3 #8-32 screw term. for main contacts, .250 (6.35mm) qc for coil. 4 box lug term. which accept #6 - #14 wire for main contacts, #6-32 screw term. for coil. 6) 6) available with main contact arrangement code (step 2 above) 3 only, and main contact material code (step 4 above) p or r only. prda (with aux. switch) types only a #8-32 screw term. for main contacts, #6-32 screw term. for coil, screw term. for aux. switch b .250 (6.35mm) qc for main contacts, coil and aux. switch l twin .250 (6.35mm) qc for main contacts, .250 (6.35mm) qc for coil and aux. switch coil voltage coil code: please refer to coil versions table terminal assignment for models with magnetic blowout prd3 with blowout prd7 with blowout prd 11 with blowout - + - - - + this side of magnet attracts north seeking pole of compass. this side of magnet attracts north seeking pole of compass. this side of magnet attracts north seeking pole of compass. polarity marking polarity marking polarity marking
general purpose relays industrial relays prd series power relay (continued) 08-2011, rev. 0811 www.te.com ? 2011 tyco electronics corporation, a te connectivity ltd. company datasheets and product specifcation according to iec 61810-1 and to be used only together with the defnitions section. datasheets and product data is subject to the terms of the disclaimer and all chapters of the defnitions section, available at http://relays.te.com/definitions datasheets, product data, defnitions sec - tion, application notes and all specifcations are subject to change. 4 potter & brumfeld product code arrangement material coil terminals part number prd-3ay0-120 1 form x, 1 no-dm ag 120vac screw 7-1393127-9 prd-3ag0-120 agcdo, 30a 6-1393127-9 prd-3aj0-120 agcdo, mag blowout 7-1393127-4 prd-3aj3-24 24vac screw / qc 7-1393127-5 prd-3dh0-24 ag, mag blowout 24vdc screw 8-1393127-6 prd-3dy0-12 ag 12vdc 9-1393127-5 prd-3dy0-24 24vdc 9-1393127-6 prd-3dy0-110 110vdc 9-1393127-4 prd-5ay0-24 1 form c, 1 co 24vac 1393128-6 prd-5ay0-120 120vac 1393128-5 prd-5ay1-120 qc 1-1393128-1 prd-5ay0-240 240vac screw 1393128-7 prd-5df0-12 agcdo, 50a 12vdc 2-1423100-4 prd-5dy0-12 ag 1-1393128-6 prd-5dy0-24 24vdc 1-1393128-7 prd-7ag0-120 2 form a, 2 no agcdo, 30a 120vac 9-1393129-5 prd-7ay0-24 ag 24vac 1393130-9 prd-7ay0-120 120vac 1393130-7 prd-7ay0-240 240vac 1-1393130-0 prd-7ay3-120 120vac screw / qc 1-1393130-2 prd-7dg0-24 agcdo, 30a 24vdc screw 1-1393130-6 prd-7dh0-48 ag, mag blowout 48vac 2-1393130-1 prd-7dy0-12 ag 12vdc 2-1393130-8 prd-7dy0-24 24vdc 2-1393130-9 prd-11af0-240 2 form c, 2 co agcdo, 50a 240vac 3-1423100-0 prd-11ag0-24 agcdo, 30a 24vac 1-1393127-1 prd-11ag0-120 120vac 1393127-9 prd-11ag0-240 240vac 1-1393127-2 prd-11ah0-120 ag, mag blowout 120vac 1-1393127-6 prd-11ay0-24 ag 24vac 2-1393127-9 prd-11ay0-120 120vac 2-1393127-6 prd-11ay0-240 240vac 3-1393127-0 prd-11ay0-480 480vac 3-1393127-1 prd-11df0-12 agcdo, 50a 12vdc 2-1423100-2 prd-11df0-110 110vdc 2-1423100-9 prd-11dg0-12 agcdo, 30a 12vdc 3-1393127-5 prd-11dg0-24 24vdc 3-1393127-8 prd-11dh0-12 ag, mag blowout 12vdc 4-1393127-7 prd-11dh0-24 24vdc 4-1393127-9 prd-11dh0-48 48vdc 5-1393127-0 prd-11dh0-110 110 vdc 4-1393127-6 prd-11dj0-24 agcdo, mag blowout 24 vdc 5-1393127-5 prd-11dy0-12 ag 12 vdc 6-1393127-1 prd-11dy0-24 24 vdc 6-1393127-2 prd-11dy0-48 48 vac 6-1393127-3 prd-11dy0-110 110 vdc 6-1393127-0 prda-11aga-120 agcdo, 30a 120 vac 7-1393131-4 prda-11aya-120 7-1393131-9 product code description part number 35d013 metal dust cover enclosure 5-1393158-2 prd accessory 3.38 max. (85.9) 3.13 max. (79.5) .97 (24.64) .093 (2.36) .75 (19.1) 1.50 (38.1) 4 knockout holes 2 knockout holes each end .88 dia. (22.4) 2.56 (65.0) .937 (23.86) 1.875 (47.63) 4.125 (104.77) 5.31 max. (134.9) .50 (12.7) .218 dia. (5.54) 3 mtg. holes 5.125 (130.18) 2.06 (52.3) .687 (17.45) .812 (20.62) 1.625 (41.28) 4 holes tapped #8-32 35d013 dust cover prd dust cover has a steel base with knockouts for 0.5? (12.7mm) dia. conduit and a cover ?tted with two screws. fits prd relays, except with auxiliary contacts. finished in gray baked enamel. mounting: three no. 10 holes on 1.875? (47.63mm) x 4.125? (104.77mm) centers. note: additional unused holes may be pr esent in dust cover base.


▲Up To Search▲   

 
Price & Availability of 2-1393128-0

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X